The use of combination lock operation
2010-3-6 18:05:10
![]()
The distinction between the direction of door locks
Left open the door: You have to stand outside the door when the door fixed hinge on the left, you have to hold hands with his left hand, screwed into the facade, when the direction of the left to open the lock; if holding the handle pull out into the facade When the direction of the lock to open the left outside.
Right hand door: You have to stand outside the door when the door of the fixed hinge in the right, you have to hold hands with the right hand, twisted to gain access when the direction is right to open the lock; if holding open the door handle Wangwai La Entering When the direction is right outside the lock to open.
Chapter advanced electronic anti-theft door lock diagram of intelligent
Chapter II advanced electronic anti-theft lock hole Smart Chart
Chapter III of the advanced electronic anti-theft locks the use of intelligence operations
Mifarc card password office, home door lock system has the following two modes:
Stand-alone: alone mifare card or password can open the door.
Combined: mifare cards and passwords before they can open the door simultaneously.
Note: 1 The system locks the factory is initialized to the management of customer intelligence code is 12345678, opened the door stand-alone mode.
1.1 From the stand-alone switch to mix mode operation is as follows:
Enter eight administrative password and then press the key button 5 by 6, sounding buzzer sound, red and blue lights flashing, then press the key button to confirm, buzzer: "drip" long been heard, a successful switch. If the exit according with "*" key.
1.2 From modular switches to stand-alone operation is as follows:
Brush management card enter the administrative password by 8 keys, press 6, Bell 5 buzzer sound, red and blue lights flashing, then press the key button to confirm, buzzer: "drip" long been heard, a successful switch. If the exit according with "*" key.
Mifare card lock Operations Guide
(1) Management Card:
Function: to set up and remove the effective open card; can be open.
(2) The door card:
Function: open the door and the provision of access lock
(3) Mechanical key
Function: Emergency door, with management cards, clear the Management Card
1, set the management card, remove the Management Card
1.1 In the lock is initialized (according to PCB board switch about 3 seconds after ringing heard, release the finger, the green light flash into the state with management cards, this time reading the card shall be the management card, the successful buzzer: "drop "long ring soon as. At the same time write-off the original management card. up to a Management Card 2.
1.2 with the mechanical key to open the door and maintain the mechanical key in the lock-shaped into about 3 seconds after ringing your voice with management the green light flash card into the state (lock state refers to the cylinder of the ramp and generous tongue tongue are shrinking into the lock body), Release the mechanical keys, time card reader shall be managed successfully buzzer: "drop" long ring soon as. At the same time write-off the original management card. Up to a Management Card 2.
2, with open cards
2.1 access with key state
Reading management cards, buzzers, "drop" sound heard, motor rotation, blue lights flashing, a time to open the door, opened the door after the lights went. If there is no door entered with key state, shall open the door card reader at this time. Within 5 seconds, locks, if not detected to a valid IC card, then the buzzer, "drip, drip," Liang Sheng Ming short, with the end key.
2.2 with key operation
Access with key state, with the IC card near the lock of the sensing area, with key success buzzer "drop" long ring heard, you can repeat this operation with the other door. If this card already exists, then the buzzer sounded a "bit" sound of two short-ming. Equipped with up to 200 cards.
Second, remove the door key
3.1 Delete a single door card
The management cards read twice near the sensing area, then the buzzer sounded, "drop" is heard ringing, red lights flashing, the card you want to delete the open area near the sensor reads, "drop" soon as a short-ming, said that the card has been removed. Repeat this operation can remove the other door cards. If this card does not exist, then the buzzer sounded a "bit" sound of two short-ming.
3.2 Delete a single door card is lost
The management cards close to the sensing area three times, then the buzzer sounded a "bit" of Liang Sheng sounding and flashing red light to a lost card before the card close to the sensing area door reads, "drops" soon as a short-ming, table is not the lost card has been deleted. If this is the first open the door card is lost, then the state of reading the last one open card.
3.3 Delete all of the door cards
The management card reading near the induction area five times, and then the buzzer sounded, "drip, drip, drip" of the three acoustic sounding, red lights flashing, and finally "drip, drip," Liang Sheng, delete completed, that is, all the doors off the original card. Of the original card can not be effectively open the door lock, and only through the master key only after re-key lock.
Note: Add a new door cards are always remove the card from the top of the location of next row.
4, door cards
4.1 IC card key door
With a valid IC card close to lock the induction zone, buzzer, "drop" is heard, motor movements, bright blue light, suggesting that the lock has been opened. Detected after the move opened the door locks automatically lock the doors; if not detected, open the door movement, 5 seconds after the green light to destroy, but also automatically lock the doors.
4.2 Mechanical key opened the door
In the electronic system failure or the battery is dead and so all cases can be the key to unlocking machine.
5, close the door alarm
5.1 were not locked Alarm
When the door closed but the ramp out of the tongue did not come out or just a part of, commonly known as: a "false lock", the locks will be issued one minutes of the siren and flashing red light, re-locked after the alarm stops.
6, normally open (channel) is set
6.1-channel settings:
After holding down the handle, the latch back years, remain intact, brush door card or the management card, buzzer long calls out, flashing a red light under the door motor movement, the door is always open (channel state).
6.2 lifting channel status:
After holding down the handle, the latch back years, remain intact, brush door card buzzer short calls out, flashing a green light under the closed motor movement, locked the door to lift the channel status. Or directly with the management card credit card to lift channel status
Note: When the door is always open state, with the door card door, "drop" a voice of short sound, and then red light. But the door lock motors do not move, because this time the door has been opened in a regular state.
Cryptographic functions Operations Guide
(1) administrative password
Function: cryptographic functions can be set up and remove the door
(2) open password
Function: open
First, change the admin password
1.1 Input of the original 8-bit password, press a button buzzer sounding and heard, red and blue lights flashing, this time enter your new password and press the key button buzzer ringing soon as the password again to confirm and press the key button blue lights, Buzzer "DDD" long ring three times, then the admin password change successful. If in the second press the key button to enter a password error after the buzzer, "subtitle of DDD" 5 sound re-enter. If the exit according to * key.
1.2 with the mechanical key to open the door and maintain the mechanical key in the lock state of about 3 seconds (unlock state refers to the cylinder of the ramp and generous tongue tongue are shrinking into the lock body), buzzer, "tick" sound soon as the long, blue lights flashing , release the keys, this time enter the 8-bit password key and press the key after confirmation buzzer ringing soon as the situation re-enter the customer code and press the key button blue lights. Buzzer "DDD" long ring three times, then the password for the new administrative password.
2, with open password
Input 8 administrative password and then press the key button press on the 8th key buzzer sounding and heard, blue light flashing, this time a 6-digit password and press the key button buzzer sounding soon as confirmation of re-enter the password just entered Press the key button blue lights, then the door buzzer ringing Liangsheng password successfully set. If in the second to enter a password wrong key buzzer according to the key "episodes DDD" 5 sound re-enter. Repeat this operation can open the door with the other password. If this password already exists, then the buzzer sounded, "DDD" in three times the short-ming. Open the door with a maximum of 50 passwords, if the exit according to * key.
3, delete or modify the open password
3.1 Delete a single door password
Enter eight administrative password and press 4 key buzzer sounding and heard, the red light flashes, enter the password you want to delete a group of pre-open passwords, "drops" soon as a short-ming, deleted successfully. If you want to delete the first group of open password, then enter the final in this state a group of open-door password. If the exit according to * key.
3.2 Remove all door password
Enter eight administrative password and press 0 key buzzer sounding and heard, the red light flashes rapidly and then enlisted the key button to confirm the buzzer sounded, "DDD's 3 acoustic sounding, red and blue lights flashing, and finally" flooding back "Liang Sheng, delete completed, that all of the door off the original password. If the exit according to * key.
3.3 The change opened the door password
Enter the original password, press 6 opened the door buzzer ringing soon as No. 1 key, red and blue lights flashing, this time enter the new password and press the key 6 key buzzer ringing soon as the password again to confirm and press the key button blue lights, then the door buzzer ringing three times a successful password change, the original open passwords. If in the second to enter a password wrong key buzzer according to the key "episodes DDD" 5 sound re-enter. If the exit according to * key.
Note: Add a new front door password is always remove the password from the location of next row.
4, open the door
4.1 Management Password Door
Enter the administrative password and press the key button, buzzer, "tick" heard, Ma moves, blue lights, indicating the lock has been opened. Detected after the move opened the door locks automatically lock the doors; if not detected, open the door movement, five seconds later, blue lights turned off, but also automatically lock the doors.
4.2 open password open the door
Enter password and press the key to open the door key, buzzer, "tick," a sound, motor movements, bright blue light, suggesting that the lock has been opened. Detected after the move opened the door locks automatically lock the doors; if not detected, open the door movement, five seconds later, blue lights turned off, but also automatically lock the doors
5, doorbell sound settings
The doorbell can be set up as many as 27 species of their own doorbell sounds. Enter the administrative password press the key button and press 3 keys, in this state, every time I press 3 keys, bell sounds automatically become one of determining doorbell sound and press "*" key to exit can be.
Note: Continuous 5 times entered the wrong keypad 5 minutes, 10 seconds after power to resume operation
If the password is invalid, then the buzzer sounded, "DDD" three times the short-ming, red light.
If the voltage is insufficient, then the buzzer sounded, "subtitle of DDD" Even the sound 5 sound, red light. The first low-voltage prompted, can open the door for more than 200 times, in order to ensure the normal use of locks should be timely replacement of the battery.
Keyboard wake up in the password state, doorbell button when 0 # keys.
6, in particular, prompted
6.1 In order for your property, we are here to remind you to lock immediately after the installation is complete change management code and remove all door passwords; the same time, using any one management card to clear all open cards (management card is 2) and then in accordance with need to open the door with the Management Card with Card
6.2 In order to improve security, the system supports open garbage features. For example: the correct password is 123456, you can in this password before and after any increase in numbers (passwords up to more than 12) in the case 012,123,456,798